How to better reduce noise in diesel generators

1
How to better reduce noise in diesel generators
How to better reduce noise in diesel generators

How can diesel generators better reduce noise during use? The diesel generator editor will take you to have a detailed understanding of this issue.

The sound-absorbing material adopts fire-resistant, high-temperature resistant, sound-absorbing, wave environmentally friendly sponge combined with 0.8mm galvanized iron plate. The perforated plate covers the box sponge, allowing noise diffusion, absorption, shock absorption, and sound insulation to reduce noise.

The intake system is designed on the top of the generator soundbox, made of galvanized iron plate for turbidity prevention and waterproofing. It is equipped with a partition sound-absorbing system and two 25000m3 explosion-proof fans per hour to force air intake and timely supplement the air required for generator operation. The exhaust and heat dissipation system timely removes polluted and waste hot air, ensuring that the temperature inside the chassis and the working temperature of the generator do not increase, achieving the goal of improving power generation efficiency, reducing fuel consumption, and extending the service life of the generator.

Install KD-KZD series bag type and medium efficiency air filters in front of the air intake box to keep the air entering the chassis fresh. It can filter out 90% or more of the dust in the air at 5 microns, remove harmful gases dissolved in water, keep the indoor air clean and hygienic, and better extend the service life of the air filter on the unit.

In order to prevent noise from being transmitted externally, sound-absorbing fins are installed in the intake and exhaust channels, as well as in the heat dissipation channels. Secondary sound-absorbing devices are installed on the exhaust pipes to achieve outdoor noise reduction. After noise control, it meets national standards. The independent control room provides a good working environment for operators to work in a noisy environment for a long time and avoid damage to their hearing and vision. It adopts an isolated and noise free operation mode, and is equipped with a 1.0 horsepower air conditioner and a data storage area. Improved the applicability of operators.

The automatic shutdown system for air intake and exhaust is used. In case of methane content, smoke exceeding the standard, or fire inside the box, the smoke alarm system is used to automatically shut down the air intake and exhaust system, cut off the air intake into the generator box, and control it in anaerobic conditions to prevent the generator from running, better protecting the safety of the generator.